Henan huixiang automation system co. LTD
Telephone: 0371-66957207
Fax: 0371-66952781
Website: www.hxyb.com.cn
E-mail:zzwap@163.com
Sales address: no.33, hall, 1 / f, new taikang electromechanical city, zhengzhou
Domestic production base: no.5 garden, no.12, dongqing street, high-tech development zone, zhengzhou
The flanged differential pressure transmitter is a differential pressure transmitter which is connected with the flange and the measured object, which is used to measure the parameters of liquid level, boundary surface and proportion. It can continuously measure the flow of liquid, steam and gas, and convert the measured parameter values into uniform standard gas pressure signals.
Single flange insert pressure transmitter parameters.
Measuring object: the liquid level of the opening or sealing vessel.
Range range: 0 ~ 2 ~ 40kPa0 ~ 12.5 ~ 200kPa0 ~ 50 ~ 1000kPa0 ~ 125 ~ 2500kPa
Output: 4mA ~ 20mA DC
Power supply :24V DC, the transmitter can work at 12V DC without load, up to 45V DC.
Communication output: power supply voltage: 16.4V ~ 42V DC(16.4V ~ 30VDC)
Communication distance: 2km, using CEV cable
Load capacitance: 0.22 mu F below
Load inductance: 3.3mH
Spacing of power lines: over 15cm.
A receiver in connection to receive resistance instrument input impedance: for more than 10 k Ω when 2.4 kHz
Indicator (site) scale of 45mm, indicating accuracy of 2.5 (pointer type) indicating accuracy of 0.5 (digital)
Dangerous places to install the flameproof type, this type.
Positive and negative transfer regardless of the output, after the positive and negative transfer, the range of the range and the limit shall not exceed the limit of the range?
Maximum positive migration: 500% of the minimum calibration range
Maximum negative transfer: 600% of the minimum calibration range.
Temperature range: amplifier working temperature 25 ℃ ~ 90 ℃ temperature sensor to 40 ℃ ~ 104 ℃ - 18 ℃ ~ 204 ℃ pump inert liquid
Relative humidity: 0 ~ 100%RH
Static pressure and overpressure limit 150 ib flange: 42 kpa (absolute pressure) ~ 1.9 MPa (37 ℃) 300 ib flange: 42 kpa (absolute pressure) ~ 4.9 MPa (37 ℃)
The change in sensor is less than 0.16cm3
Damping: the time constant can be adjusted continuously between 0.2 ~ 1.67 seconds.
Start time: 2s, do not need to preheat
Accuracy: 0.25% of calibration range, including linear, variable and repetitive errors
Stability: maximum range of + + 0.5%(12 months)
Communication output: communication distance: 1.2Km (using CEV cable) 1, 4mA ~ 20mA DC output + field bus HART
Protocol communication distance: 2Km (using CEV cable) 2, 4mA ~ 20mA Dc output
Vibration influence: on any axis, the frequency is 200Hz, resulting in the error of the maximum range of 0.05%/V
Power impact: 0.005%/V less than the input range
Load impact: as long as the terminal voltage of the input transmitter is higher than 12V, there is no load effect
Effect of installation position: the minimum error of 0.25kpa can be produced, but it can be corrected, no impact on the range, and can be corrected and eliminated.
Structural material: isolation diaphragm :316 stainless steel insert part :316L"O" ring (contact with measuring medium) : fluorine rubber.
Flange and bolt: 316 stainless steel
Filling fluid: silicone oil or inert liquid
Electrical shell: low copper aluminum alloy.
Electrical shell coating: polyurethanate resin baking varnish
Pressure connector: high pressure side 3 "or 4", 150Ib or 300Ib flanges, low pressure side flange connection thread 1/4-NPT (taper pipe thread).
Connector thread 1/2-NPT (this item is selected).
Electrical connection: conduit 1/2G or M20 x 1.5 threading hole
Weight: transformer body 4.9 Kg. Other technical parameters are in the WIDEPLUS LT series
Flange dimensions and bolt hole specifications
法 兰 尺 寸(mm) | 螺 栓 孔(mm) | ||||||||
订货代号 | 尺寸 | 额定压力 | 外直径 | A | B | C | 数目 | 孔直径 | 孔分布直径 |
A | 3" | 150Ib | 190.5 | 30 | 66 | 127 | 4 | 19 | 152 |
B | 4" | 150Ib | 228.6 | 30 | 89 | 157 | 8 | 19 | 190 |
C | 3" | 300Ib | 209.6 | 35 | 66 | 127 | 8 | 22.2 | 168 |
D | 4" | 300Ib | 254.0 | 38 | 89 | 157 | 8 | 22.2 | 200 |